• Thumbnail for Cryostat
    A cryostat (from cryo meaning cold and stat meaning stable) is a device used to maintain low cryogenic temperatures of samples or devices mounted within...
    8 KB (1,153 words) - 20:55, 20 April 2024
  • Thumbnail for Superconducting magnet
    thermally insulated container (dewar) called a cryostat. To keep the helium from boiling away, the cryostat is usually constructed with an outer jacket containing...
    29 KB (3,689 words) - 23:13, 1 April 2024
  • Thumbnail for ITER
    ITER (section Cryostat)
    Larsen & Toubro completed the delivery and installation of the cryostat module. The cryostat is the major component of the tokamak complex, which sits on...
    143 KB (14,905 words) - 20:29, 12 May 2024
  • Thumbnail for Frozen section procedure
    procedure (Gal & Cagle, 2005). The key instrument for cryosection is the cryostat, which is essentially a microtome inside a freezer. The microtome can be...
    11 KB (1,323 words) - 23:55, 13 October 2023
  • Thumbnail for Optimal cutting temperature compound
    used to embed tissue samples prior to frozen sectioning on a microtome-cryostat. This process is undertaken so as to mount slices (sections) of a sample...
    1 KB (104 words) - 17:24, 30 September 2016
  • Thumbnail for Orbital propellant depot
    Propellant STorage And Transfer (CRYOSTAT) Mission". The CRYOSTAT vehicle was expected to be launched to LEO in 2015. The CRYOSTAT architecture comprises technologies...
    73 KB (7,943 words) - 20:22, 15 May 2024
  • Thumbnail for Submillimeter Array
    focus. All receivers are mounted in a single large cryostat within the antenna cabin. The cryostat can accommodate up to eight receiver inserts, each...
    18 KB (2,234 words) - 16:09, 28 August 2023
  • Thumbnail for Dilution refrigerator
    is circulated by vacuum pumps at room temperature. The 3He enters the cryostat at a pressure of a few hundred millibar. In the classic dilution refrigerator...
    13 KB (1,687 words) - 19:27, 3 September 2023
  • Thumbnail for Lowest temperature recorded on Earth
    low temperatures". Archived from the original on 18 June 2009. Retrieved 13 February 2019. Details of HUT experiment, including details of the cryostat...
    10 KB (1,159 words) - 15:20, 12 February 2024
  • Thumbnail for H&E stain
    stain in Mohs surgery in which tissues are typically frozen, cut on a cryostat (a microtome that cuts frozen tissue), fixed in alcohol, and then stained...
    16 KB (1,588 words) - 08:23, 14 May 2024
  • A cryostat made of fiberglass...
    38 KB (4,632 words) - 02:53, 11 April 2024
  • Headquarters Wetzlar, Germany Key people Markus Lusser Products Microtome; Cryostat; Vibratome Parent Danaher Corporation Website www.leicabiosystems.com...
    3 KB (243 words) - 16:24, 23 March 2024
  • Thumbnail for Mohs surgery
    freezing and cutting the tissue between 5 and 10 micrometres using a cryostat, and staining with hematoxylin and eosin (H&E) or other stains (Including...
    25 KB (3,095 words) - 16:46, 8 September 2023
  • two antigen retrieval methods designed specifically for aldehyde-fixed cryostat frozen tissue sections or cultured cells; the SDS and Heating En Bloc methods...
    4 KB (419 words) - 18:15, 26 October 2023
  • Thumbnail for Histopathology
    microtome mounted in a below-freezing refrigeration device called the cryostat. The thin frozen sections are mounted on a glass slide, fixed immediately...
    15 KB (1,636 words) - 07:47, 3 May 2024
  • Thumbnail for Deuterium
    weapon. At its center, a very large cylindrical, insulated vacuum flask or cryostat, held cryogenic liquid deuterium in a volume of about 1000 liters (160...
    71 KB (8,805 words) - 20:35, 12 May 2024
  • Thumbnail for Histology
    sections of tissue for histology. The tissue is usually sectioned on a cryostat or freezing microtome. The frozen sections are mounted on a glass slide...
    33 KB (3,175 words) - 02:19, 19 May 2024
  • Thumbnail for In situ hybridization
    hybridization processing include cutting specimens with a cryostat or a Compresstome tissue slicer. A cryostat takes fresh or fixed tissue and immerses it into...
    12 KB (1,318 words) - 20:10, 14 May 2024
  • Thumbnail for Simons Observatory
    construction. The detectors on the LAT will be housed in a single large cryostat over 2.4 meters in diameter. This will house up to 13 optics tubes consisting...
    10 KB (1,188 words) - 11:11, 20 May 2024
  • Thumbnail for Gran Telescopio Canarias
    CanariCam was a very compact design. It was designed for a total weight of the cryostat and its on-telescope electronics to be under 400 kg.[citation needed] Most...
    11 KB (1,088 words) - 04:28, 12 May 2024
  • Thumbnail for CUORE
    low heat capacity bolometers, arranged into towers and cooled in a large cryostat to approximately 10 mK with a dilution refrigerator. The detectors are...
    19 KB (2,135 words) - 08:18, 8 March 2024
  • High Luminosity LHC – clusterD test station vertical cryostat installation seen in CERN's magnet test facility (SM18)....
    30 KB (3,364 words) - 04:37, 22 March 2024
  • Thumbnail for Cosmic Background Explorer
    90 GHz. The radiometers are distributed around the outer surface of the cryostat. Each radiometer employs a pair of horn antennas viewing at 30° from the...
    34 KB (4,023 words) - 18:16, 1 January 2024
  • Thumbnail for Michelson–Morley experiment
    frequencies of two Nd:YAG lasers, are set at right angles within a helium cryostat. A frequency comparator measures the beat frequency of the combined outputs...
    89 KB (10,257 words) - 18:59, 10 May 2024
  • Thumbnail for Wendelstein 7-X
    quasi-isodynamic principle. The main components are the magnetic coils, cryostat, plasma vessel, divertor and heating systems. The coils (NbTi in aluminium)...
    32 KB (2,986 words) - 00:50, 25 January 2024
  • The cryostat and shield of XENON100. The shield consists of an outer layer of 20 cm of water, a 20 cm layer of lead, a 20 cm layer of polyethylene, and...
    26 KB (3,055 words) - 19:44, 4 December 2023
  • Thumbnail for Large Binocular Telescope
    is operated at cryogenic temperatures, and is therefore enclosed in a cryostat of 1.6 m diameter and 1.6 m height, and cooled to about −200 °C by two...
    21 KB (2,123 words) - 19:28, 15 May 2024
  • Thumbnail for Electromagnet
    current (2017) record of 32 T. The necessary refrigeration equipment and cryostat make them much more expensive than ordinary electromagnets. However, in...
    50 KB (5,574 words) - 08:40, 2 May 2024
  • first of the Cryostats went into use early in 1947.: A 1948 Life Magazine spread on “Absolute Zero,” featuring the Collins Helium Cryostat, publicized...
    15 KB (2,062 words) - 01:32, 24 March 2024
  • Thumbnail for Permittivity
    nearly 21 orders of magnitude from 10−6 to 1015 hertz. Also, by using cryostats and ovens, the dielectric properties of a medium can be characterized...
    34 KB (4,422 words) - 10:19, 7 May 2024