QT interval

QT interval
Electrocardiogram showing QT interval calculated by tangent method
ICD-10-PCSR94.31
ICD-9-CM89.52
MeSHD004562
MedlinePlus003868

The QT interval is a measurement made on an electrocardiogram used to assess some of the electrical properties of the heart. It is calculated as the time from the start of the Q wave to the end of the T wave, and approximates to the time taken from when the cardiac ventricles start to contract to when they finish relaxing. An abnormally long or abnormally short QT interval is associated with an increased risk of developing abnormal heart rhythms and sudden cardiac death. Abnormalities in the QT interval can be caused by genetic conditions such as long QT syndrome, by certain medications such as sotalol or pitolisant, by disturbances in the concentrations of certain salts within the blood such as hypokalaemia, or by hormonal imbalances such as hypothyroidism.

Measurement[edit]

Illustrations of the tangent and threshold methods of measuring the QT interval

The QT interval is most commonly measured in lead II for evaluation of serial ECGs, with leads I and V5 being comparable alternatives to lead II. Leads III, aVL and V1 are generally avoided for measurement of QT interval.[1] The accurate measurement of the QT interval is subjective[2] because the end of the T wave is not always clearly defined and usually merges gradually with the baseline. QT interval in an ECG complex can be measured manually by different methods, such as the threshold method, in which the end of the T wave is determined by the point at which the component of the T wave merges with the isoelectric baseline, or the tangent method, in which the end of the T wave is determined by the intersection of a tangent line extrapolated from the T wave at the point of maximum downslope to the isoelectric baseline.[3]

With the increased availability of digital ECGs with simultaneous 12-channel recording, QT measurement may also be done by the 'superimposed median beat' method. In the superimposed median beat method, a median ECG complex is constructed for each of the 12 leads. The 12 median beats are superimposed on each other and the QT interval is measured either from the earliest onset of the Q wave to the latest offset of the T wave or from the point of maximum convergence for the Q wave onset to the T wave offset.[4]

Correction for heart rate[edit]

The QT interval changes in response to the heart rate - as heart rate increase the QT interval shortens. These changes make it harder to compare QT intervals measured at different heart rates. To account for this, and thereby improve the reliability of QT measurement, the QT interval can be corrected for heart rate (QTc) using a variety of mathematical formulae, a process often performed automatically by modern ECG recorders.

Bazett's formula[edit]

The most commonly used QT correction formula is the Bazett's formula,[5] named after physiologist Henry Cuthbert Bazett (1885–1950),[6] calculating the heart rate-corrected QT interval (QTcB).

Bazett's formula is based on observations from a study in 1920. Bazett's formula is often given in a form that returns QTc in dimensionally suspect units, square root of seconds. The mathematically correct form of Bazett's formula is:

where QTcB is the QT interval corrected for heart rate, and RR is the interval from the onset of one QRS complex to the onset of the next QRS complex. This mathematically correct formula returns the QTc in the same units as QT, generally milliseconds.[7]

In some popular forms of this formula, it is assumed that QT is measured in milliseconds and that RR is measured in seconds, often derived from the heart rate (HR) as 60/HR. Therefore, the result will be given in seconds per square root of milliseconds.[8] However, reporting QTc using this formula creates a "requirement regarding the units in which the original QT and RR are measured."[7]

In either form, Bazett's non-linear QT correction formula is generally not considered accurate, as it over-corrects at high heart rates and under-corrects at low heart rates.[8] Bazett's correction formula is one of the most suitable QT correction formulae for neonates.[9]

Fridericia's formula[edit]

Fridericia[10] had proposed an alternative correction formula (QTcF) using the cube-root of RR.

Failed to parse (SVG (MathML can be enabled via browser plugin): Invalid response ("Math extension cannot connect to Restbase.") from server "http://localhost:6011/en.wikipedia.org/v1/":): {\displaystyle QTc_F = {QT \over \sqrt[3]{RR \over 1\text{ s}}}}

Sagie's formula[edit]

The Framingham correction, also called as Sagie's formula based on the Framingham Heart Study, which used long-term cohort data of over 5,000 subjects, is considered a better[11] method.[12]

Again, here QT and QTlc are in milliseconds and RR is measured in seconds.

Comparison of corrections[edit]

A retrospective study suggests that Fridericia's method and the Framingham method may produce results most useful for stratifying the 30-day and 1-year risks of mortality.[11]

Upper limit of normal QT interval, corrected for heart rate according to Bazett's formula,[5] Fridericia's formula,[10] and subtracting 0.02 s from QT for every 10 bpm increase in heart rate.[13] Up to 0.42 s (≤ 420 ms) is chosen as normal QTc of QTB and QTF in this diagram.[14]

Definitions of normal QTc vary from being equal to or less than 0.40 s (≤ 400 ms),[13] 0.41 s (≤ 410 ms),[15] 0.42 s (≤ 420 ms)[14] or 0.44 s (≤ 440 ms).[16] For risk of sudden cardiac death, "borderline QTc" in males is 431–450 ms; and, in females, 451–470 ms. An "abnormal" QTc in males is a QTc above 450 ms; and, in females, above 470 ms.[17]

If there is not a very high or low heart rate, the upper limits of QT can roughly be estimated by taking QT = QTc at a heart rate of 60 beats per minute (bpm), and subtracting 0.02 s from QT for every 10 bpm increase in heart rate. For example, taking normal QTc ≤ 0.42 s, QT would be expected to be 0.42 s or less at a heart rate of 60 bpm. For a heart rate of 70 bpm, QT would roughly be expected to be equal to or below 0.40 s. Likewise, for 80 bpm, QT would roughly be expected to be equal to or below 0.38 s.[13]

Abnormal intervals[edit]

Prolonged QTc causes premature action potentials during the late phases of depolarization. This increases the risk of developing ventricular arrhythmias, including fatal ventricular fibrillation.[18] Higher rates of prolonged QTc are seen in females, older patients, high systolic blood pressure or heart rate, and short stature.[19] Prolonged QTc is also associated with ECG findings called Torsades de Pointes, which are known to degenerate into ventricular fibrillation, associated with higher mortality rates. There are many causes of prolonged QT intervals, acquired causes being more common than genetic.[20]

Genetic causes[edit]

Distribution of QT intervals amongst healthy males and females, and amongst those with congenital long QT syndrome

An abnormally prolonged QT interval could be due to long QT syndrome, whereas an abnormally shortened QT interval could be due to short QT syndrome.

The QTc length is associated with variations in the NOS1AP gene.[21] The autosomal recessive syndrome of Jervell and Lange-Nielsen is characterized by a prolonged QTc interval in conjunction with sensorineural hearing loss.

Due to adverse drug reactions[edit]

Prolongation of the QT interval may be due to an adverse drug reaction.[22]

Antipsychotics (especially first generation/"typical")

DMARDs and antimalarial drugs

Antibiotics

Other drugs

Some second-generation antihistamines, such as astemizole, have this effect. The mechanism of action of certain antiarrhythmic drugs, like amiodarone or sotalol, involve intentional pharmacological QT prolongation. In addition, high blood alcohol concentrations prolong the QT interval.[30] A possible interaction between selective serotonin reuptake inhibitors and thiazide diuretics is associated with QT prolongation.[31]

Due to pathological conditions[edit]

Hypothyroidism, a condition of low function of the thyroid gland, can cause QT prolongation at the electrocardiogram. Acute hypocalcemia causes prolongation of the QT interval, which may lead to ventricular dysrhythmias.

A shortened QT can be associated with hypercalcemia.[32]

Use in drug approval studies[edit]

Since 2005, the FDA and European regulators have required that nearly all new molecular entities be evaluated in a Thorough QT (TQT) or similar study to determine a drug's effect on the QT interval.[33] The TQT study serves to assess the potential arrhythmia liability of a drug. Traditionally, the QT interval had been evaluated by having an individual human reader measure approximately nine cardiac beats per clinical timepoint. However, a substantial portion of drug approvals after 2010 have incorporated a partially automated approach, blending automated software algorithms with expert human readers reviewing a portion of the cardiac beats, to enable the assessment of significantly more beats in order to improve precision and reduce cost.[34] In 2014, an industrywide consortium consisting of the FDA, iCardiac Technologies and other organizations released the results of a seminal study indicating how waivers from TQT studies can be obtained by the assessment of early phase data.[35] As the pharmaceutical industry has gained experience in performing TQT studies, it has also become evident that traditional QT correction formulas such as QTcF, QTcB, and QTcLC may not always be suitable for evaluation of drugs impacting autonomic tone.[36]

As a predictor of mortality[edit]

Electrocardiography is a safe and noninvasive tool that can be used to identify those with a higher risk of mortality. In the general population, there has been no consistent evidence that prolonged QTc interval in isolation is associated with an increase in mortality from cardiovascular disease.[37] However, several studies[which?] have examined prolonged QT interval as a predictor of mortality for diseased subsets of the population.

Rheumatoid arthritis[edit]

Rheumatoid arthritis is the most common inflammatory arthritis.[38] Studies have linked rheumatoid arthritis with increased death from cardiovascular disease.[38] In a 2014 study,[18] Panoulas et al. found a 50 ms increase in QTc interval increased the odds of all-cause mortality by 2.17 in patients with rheumatoid arthritis. Patients with the highest QTc interval (> 424 ms) had higher mortality than those with a lower QTc interval. The association was lost when calculations were adjusted for C-reactive protein levels. The researchers proposed that inflammation prolonged the QTc interval and created arrhythmias that were associated with higher mortality rates. However, the mechanism by which C-reactive protein is associated with the QTc interval is still not understood.

Type 1 diabetes[edit]

Compared to the general population, type 1 diabetes may increase the risk of mortality, due largely to an increased risk of cardiovascular disease.[19][39] Almost half of patients with type 1 diabetes have a prolonged QTc interval (> 440 ms).[19] Diabetes with a prolonged QTc interval was associated with a 29% mortality over 10 years in comparison to 19% with a normal QTc interval.[19] Anti-hypertensive drugs increased the QTc interval, but were not an independent predictor of mortality.[19]

Type 2 diabetes[edit]

QT interval dispersion (QTd) is the maximum QT interval minus the minimum QT interval, and is linked with ventricular repolarization.[40] A QTd over 80 ms is considered abnormally prolonged.[41] Increased QTd is associated with mortality in type 2 diabetes.[41] QTd is a better predictor of cardiovascular death than QTc, which was unassociated with mortality in type 2 diabetes.[41] QTd higher than 80 ms had a relative risk of 1.26 of dying from cardiovascular disease compared to a normal QTd.

See also[edit]

References[edit]

  1. ^ Panicker GK, Salvi V, Karnad DR, Chakraborty S, Manohar D, Lokhandwala Y, Kothari S (2014). "Drug-induced QT prolongation when QT interval is measured in each of the 12 ECG leads in men and women in a thorough QT study". Journal of Electrocardiology. 47 (2): 155–157. doi:10.1016/j.jelectrocard.2013.11.004. PMID 24388488.
  2. ^ Panicker GK, Karnad DR, Joshi R, Shetty S, Vyas N, Kothari S, Narula D (January 2009). "Z-score for benchmarking reader competence in a central ECG laboratory". Annals of Noninvasive Electrocardiology. 14 (1): 19–25. doi:10.1111/j.1542-474X.2008.00269.x. PMC 6932360. PMID 19149789.
  3. ^ Panicker GK, Karnad DR, Natekar M, Kothari S, Narula D, Lokhandwala Y (2009). "Intra- and interreader variability in QT interval measurement by tangent and threshold methods in a central electrocardiogram laboratory". Journal of Electrocardiology. 42 (4): 348–352. doi:10.1016/j.jelectrocard.2009.01.003. PMID 19261293.
  4. ^ Salvi V, Karnad DR, Panicker GK, Natekar M, Hingorani P, Kerkar V, et al. (2011). "Comparison of 5 methods of QT interval measurements on electrocardiograms from a thorough QT/QTc study: effect on assay sensitivity and categorical outliers". Journal of Electrocardiology. 44 (2): 96–104. doi:10.1016/j.jelectrocard.2010.11.010. PMID 21238976.
  5. ^ a b Bazett HC (1920). "An analysis of the time-relations of electrocardiograms". Heart (7): 353–370.
  6. ^ Roguin A (March 2011). "Henry Cuthbert Bazett (1885-1950)--the man behind the QT interval correction formula". Pacing and Clinical Electrophysiology. 34 (3): 384–388. doi:10.1111/j.1540-8159.2010.02973.x. PMID 21091739. S2CID 43739886.
  7. ^ a b Molnar J, Weiss JS, Rosenthal JE (March 1995). "The missing second: what is the correct unit for the Bazett corrected QT interval?". The American Journal of Cardiology. 75 (7): 537–538. doi:10.1016/S0002-9149(99)80603-1. PMID 7864010.
  8. ^ a b Salvi V, Karnad DR, Panicker GK, Kothari S (January 2010). "Update on the evaluation of a new drug for effects on cardiac repolarization in humans: issues in early drug development". British Journal of Pharmacology. 159 (1): 34–48. doi:10.1111/j.1476-5381.2009.00427.x. PMC 2823350. PMID 19775279.
  9. ^ Stramba-Badiale M, Karnad DR, Goulene KM, Panicker GK, Dagradi F, Spazzolini C, et al. (August 2018). "For neonatal ECG screening there is no reason to relinquish old Bazett's correction". European Heart Journal. 39 (31): 2888–2895. doi:10.1093/eurheartj/ehy284. PMID 29860404.
  10. ^ a b Fridericia LS (1920). "The duration of systole in the electrocardiogram of normal subjects and of patients with heart disease". Acta Medica Scandinavica (53): 469–486.
  11. ^ a b Vandenberk B, Vandael E, Robyns T, Vandenberghe J, Garweg C, Foulon V, Ector J, Willems R (2016-06-17), "Which QT Correction Formulae to Use for QT Monitoring?", Journal of the American Heart Association, 5 (6), doi:10.1161/JAHA.116.003264, PMC 4937268, PMID 27317349
  12. ^ Sagie A, Larson MG, Goldberg RJ, Bengtson JR, Levy D (September 1992). "An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study)". The American Journal of Cardiology. 70 (7): 797–801. doi:10.1016/0002-9149(92)90562-D. PMID 1519533.[need full text]
  13. ^ a b c Yanowitz FG. "Lesson III. Characteristics of the Normal ECG". University of Utah School of Medicine. Retrieved 23 March 2010.
  14. ^ a b Jenkins D, Gerred S. "A normal adult 12-lead ECG". ecglibrary.com. Retrieved 28 January 2018.
  15. ^ Fitz M. "Medicine I". Loyola University Chicago Stritch School of Medicine. Retrieved 23 March 2010.
  16. ^ Klabunde RE. "Image for Cardiovascular Physiology Concepts > Electrocardiogram (EKG, ECG)".
  17. ^ "QTc Prolongation and Risk of Sudden Cardiac Death: Is the Debate Over?". CRM News. 3 February 2006 – via medscape.com.
  18. ^ a b Panoulas VF, Toms TE, Douglas KM, Sandoo A, Metsios GS, Stavropoulos-Kalinoglou A, Kitas GD (January 2014). "Prolonged QTc interval predicts all-cause mortality in patients with rheumatoid arthritis: an association driven by high inflammatory burden". Rheumatology. 53 (1): 131–137. doi:10.1093/rheumatology/ket338. PMID 24097136.
  19. ^ a b c d e Rossing P, Breum L, Major-Pedersen A, Sato A, Winding H, Pietersen A, et al. (March 2001). "Prolonged QTc interval predicts mortality in patients with Type 1 diabetes mellitus". Diabetic Medicine. 18 (3): 199–205. doi:10.1046/j.1464-5491.2001.00446.x. PMID 11318840. S2CID 38600053.
  20. ^ van Noord C, Eijgelsheim M, Stricker BH (July 2010). "Drug- and non-drug-associated QT interval prolongation". British Journal of Clinical Pharmacology. 70 (1): 16–23. doi:10.1111/j.1365-2125.2010.03660.x. PMC 2909803. PMID 20642543.
  21. ^ Arking DE, Pfeufer A, Post W, Kao WH, Newton-Cheh C, Ikeda M, et al. (June 2006). "A common genetic variant in the NOS1 regulator NOS1AP modulates cardiac repolarization". Nature Genetics. 38 (6): 644–651. doi:10.1038/ng1790. PMID 16648850. S2CID 12942685.
  22. ^ Leitch A, McGinness P, Wallbridge D (September 2007). "Calculate the QT interval in patients taking drugs for dementia". BMJ. 335 (7619): 557. doi:10.1136/bmj.39020.710602.47. PMC 1976518. PMID 17855324.
  23. ^ "Information for Healthcare Professionals: Haloperidol (marketed as Haldol, Haldol Decanoate and Haldol Lactate)". Food and Drug Administration. Archived from the original on 2007-10-11. Retrieved 2007-09-18.
  24. ^ a b c Washington NB, Brahm NC, Kissack J (1 October 2012). "Which psychotropics carry the greatest risk of QTc prolongation?". Current Psychiatry. 11 (10): 36–39. Retrieved 2020-05-19.
  25. ^ Lewis R, Bagnall AM, Leitner M (July 2005). "Sertindole for schizophrenia". The Cochrane Database of Systematic Reviews (3): CD001715. doi:10.1002/14651858.CD001715.pub2. PMC 7025766. PMID 16034864.
  26. ^ a b c Malloy T (March 25, 2020). "Guidance on patients at risk of drug-induced sudden cardiac death from off-label COVID-19 treatments". Mayo Clinic News Network. Retrieved 2020-05-19.
  27. ^ Briasoulis A, Agarwal V, Pierce WJ (2011). "QT prolongation and torsade de pointes induced by fluoroquinolones: infrequent side effects from commonly used medications". Cardiology. 120 (2): 103–110. doi:10.1159/000334441. PMID 22156660. S2CID 39533896.
  28. ^ Haigney M. "Cardiotoxicity of methadone" (PDF). Director of Cardiology. Retrieved 21 February 2013.
  29. ^ https://wakix.com "WAKIX prolongs the QT interval; avoid use of WAKIX in patients with known QT prolongation or in combination with other drugs known to prolong QT interval."
  30. ^ Aasebø W, Erikssen J, Jonsbu J, Stavem K (April 2007). "ECG changes in patients with acute ethanol intoxication". Scandinavian Cardiovascular Journal. 41 (2): 79–84. doi:10.1080/14017430601091698. PMID 17454831. S2CID 11828588.
  31. ^ Tatonetti NP, Ye PP, Daneshjou R, Altman RB (March 2012). "Data-driven prediction of drug effects and interactions". Science Translational Medicine. 4 (125): 125ra31. doi:10.1126/scitranslmed.3003377. PMC 3382018. PMID 22422992.
  32. ^ Skugor M (June 2019). "Hypercalcemia". The Cleveland Clinic.
  33. ^ "E14 Clinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential for Non-Antiarrhythmic Drugs" (PDF). Guidance for Industry. U.S. Food and Drug Administration. October 2005. Archived from the original (PDF) on March 6, 2010. Retrieved December 9, 2009.
  34. ^ "iCardiac Applies Automated Approach to Thorough QT Study for a Leading Pharmaceutical Company – Applied Clinical Trials". 5 October 2011. Archived from the original on 5 October 2011. Retrieved 19 March 2018.{{cite web}}: CS1 maint: bot: original URL status unknown (link)
  35. ^ Or A (2014-12-16). "Norwest-Backed iCardiac to Expand Its Market Thanks to Breakthrough". Wall Street Journal. ISSN 0099-9660. Retrieved 2021-01-26.
  36. ^ Garnett C (29 April 2009). "CSRC White Paper: QT/QTc Evaluation for Drugs with Autonomic Effects" (PDF). THEW Annual Meeting. Retrieved 6 June 2014.
  37. ^ Montanez A, Ruskin JN, Hebert PR, Lamas GA, Hennekens CH (May 2004). "Prolonged QTc interval and risks of total and cardiovascular mortality and sudden death in the general population: a review and qualitative overview of the prospective cohort studies". Archives of Internal Medicine. 164 (9): 943–948. doi:10.1001/archinte.164.9.943. PMID 15136301.
  38. ^ a b Solomon DH, Karlson EW, Rimm EB, Cannuscio CC, Mandl LA, Manson JE, et al. (March 2003). "Cardiovascular morbidity and mortality in women diagnosed with rheumatoid arthritis". Circulation. 107 (9): 1303–1307. doi:10.1161/01.cir.0000054612.26458.b2. PMID 12628952.
  39. ^ Borch-Johnsen K, Andersen PK, Deckert T (August 1985). "The effect of proteinuria on relative mortality in type 1 (insulin-dependent) diabetes mellitus". Diabetologia. 28 (8): 590–596. doi:10.1007/bf00281993. PMID 4054448.
  40. ^ Okin PM, Devereux RB, Howard BV, Fabsitz RR, Lee ET, Welty TK (2000). "Assessment of QT interval and QT dispersion for prediction of all-cause and cardiovascular mortality in American Indians: The Strong Heart Study". Circulation. 101 (1): 61–66. doi:10.1161/01.cir.101.1.61. PMID 10618305.
  41. ^ a b c Giunti S, Gruden G, Fornengo P, Barutta F, Amione C, Ghezzo G, et al. (March 2012). "Increased QT interval dispersion predicts 15-year cardiovascular mortality in type 2 diabetic subjects: the population-based Casale Monferrato Study". Diabetes Care. 35 (3): 581–583. doi:10.2337/dc11-1397. PMC 3322722. PMID 22301117.

External links[edit]